Systematic Electrical Design Engineer experienced in managing electrical project from design phase to delivery and implementation. Polished in analyzing, troubleshooting and developing solutions. Consistently delivers engineering services to meet company, customer and statutory and regulatory specifications on time and within budget.
· Designed, Analyzed and provided cathodic protection solutions for over 10000+ pipeline kms for Oil & Natural Gas companies such as GAIL India, IOCL, HPCL & BPCL
· Provided earthing design and safety solution for iconic projects including World’s tallest statue – Statue of Unity –Kevadia, Gujarat.
· Associated with M/s Larsen & Turbo in design support for Lightning protection system as per IS/IEC 62305 for World’s Largest Cricket Stadium Motera Stadium in Ahmedabad, Gujarat.
· Developed KML mapping tool using Open Street map and Google Earth Pro for Transmission line profiling which reduced profiling time from 200 man hours to 48 man hours.
· Received appreciation letters from GAIL & IOCL clients for reducing mitigation costs around 40% using optimization techniques.
· Received appreciation letter from HPCL for resolving complicated mitigations in non-feasible geographical areas.
· Used Microsoft Excel to develop Transmission line parameter calculations for accuracy and ease of software modeling.
Organized the team for virtual conference of CORCON-2021 and several other NACE conferences for creating awareness about industry trends.
· Electromagnetic Interference Analysis in Oil & Gas Pipelines. · Cathodic Protection
· Substation (AIS, GIS, PV) Earthing design. · AutoCAD 2D & 3D Design
· Rail Potential analysis using CDEGS · Cable design using CDEGS
· IEEE 80 2013 – Guide for AC Grounding in Substations
· IEEE 81 2012 – Guide for earth resistivity, Ground Impedance
· IS 3043 - Code of Practice for Earthing
· ASTM G5 - 06 R 2012 – Soil Resistivity measures
· NACE SP 0177-2014 - Mitigation of AC & Lightning effects on metallic structure.
· ISO 18086 - Corrosion of metal &Alloy
· Electromagnetic Interference Analysis in Oil & Gas Pipelines. · Cathodic Protection
· Substation (AIS, GIS, PV) Earthing design. · AutoCAD 2D & 3D Design
· Rail Potential analysis using CDEGS · Cable design using CDEGS
· IEEE 80 2013 – Guide for AC Grounding in Substations
· IEEE 81 2012 – Guide for earth resistivity, Ground Impedance
· IS 3043 - Code of Practice for Earthing
· ASTM G5 - 06 R 2012 – Soil Resistivity measures
· NACE SP 0177-2014 - Mitigation of AC & Lightning effects on metallic structure.
· ISO 18086 - Corrosion of metal &Alloy