An operations and maintenance professional with a strong track record of achieving results, having worked on utility and data center projects for more than 13.7 years.
Site setup, Team building and Operation & maintenance of Data Centre infra infrastructure capacity up to 90 MW.
Rack Allocation and Management ensures optimal data center efficiency by identifying available rack space, allocating racks based on equipment requirements (power, cooling, weight, connectivity), and adhering to best practices for structured cabling and airflow management.
Actively involved and implemented power system study like load flow, short circuit study, Relay setting and coordination study and Arc flash study.
Witness FAT , SAT and carried out the IST (Integrated system test) Mechanical, Electrical and IBMS equipment.
Activity involves in review of DBR, SOW, SOO, BIM Coordination, Drawings and technical data sheets review, Project schedule preparation & tracking, support to execution team for any hurdles, monitoring & controlling activity, preparation of monthly cash flow.
Operation, maintenance of 220kV/11kV GIS Substation system substation & its switchgear which Include Breaker, CRP panel, SCADA, NIFPS system.
Overview
14
14
years of professional experience
1
1
Certification
Work History
Senior Manager, SME Electrical
CapitaLand Data center
Navi Mumbai
05.2024 - Current
Design review and proposing valid changes.
BIM Coordination.
ITC of 220 kV GIS.
Drawings review.
Value addition in design for redundancy improvement, and cost optimization.
Compliance management.
Selection of the team for the new site setup.
Policy and process set up according to various audit standards for the new site.
Setting up CRM and ITSM service software with workflow design reviews, UATs.
Data Center Manager
NTT global data center and cloud infrastructure
Navi Mumbai
08.2021 - 05.2024
Operation and maintenance of data center infrastructure, with a capacity of 90 MW, which includes transformers, UPS, PDU, DG, HVAC system, FAS system, and BMS system.
Operation and maintenance of the 220 kV/11 kV GIS substation system and its switchgear, which includes the breaker, CRP panel, SCADA, and NIFPS system.
I witnessed and carried out the FAT (Factory Acceptance Test), SAT (Site Acceptance Test) for equipment such as power transformers, dry-type transformers, UPS, DG, PAHU, and electrical HT and LT panels.
Witnessed and carried out the IST (Integrated System Test) for mechanical, electrical, and IBMS equipment.
Actively involved in and implemented power system studies, such as load flow, short circuit study, relay setting and coordination study, and arc flash study.
Set up the process for the data center and the formation of a facility team for day-to-day operations using DCOP (Data Center Operation Program).
Preparing reports such as the monthly consumption report, rack capacity report, fuel consumption report, and maintaining CAPEX and OPEX.
Maintaining the inventory, AMC of equipment, and system upgradation through the procurement process.
Tracking and maintaining the statutory compliance documents.
Use of ServiceNow for the change management system for planned and pre-approved activities.
Well-versed in the knowledge of new cooling technologies, such as DCLC and LIC, and their O&M.
ISO 50001:2018 and TIA-942B certification.
Participated in the audit and successfully achieved the certification.
Actively involved in the business purpose of the DC visit, customer audits fulfill the requirements of the same.
Deputy Manager
Godrej & Boyce Mfg. Co. Ltd
Mumbai
06.2018 - 08.2021
Managed data center infrastructure: PDU, UPS, DG, chillers, cooling towers, and FAS.
Operated and maintained 22 kV/0.415 kV substations, including SF6, VCB, ACB, and 6 MVA transformers, along with the HVAC system.
Managed data center infrastructure: PDU, UPS, DG, chillers, cooling towers and FAS.
Performed relay coordination for HT and LT systems to ensure fault discrimination.
Coordinated maintenance of chillers, compressors, HVAC, and cooling towers.
Planned and executed maintenance schedules, maintained records, and CAPA reports.
Electrical Engineer
Deepak Fertilizer and Petrochemical Ltd.
Mumbai
06.2011 - 03.2015
Operated, maintained, and troubleshot 22 kV substation equipment, control and relay panels, battery chargers, battery banks, and transformers (ONAF/ONAN/AN) up to 12.5 MVA.
Managed the operation, maintenance, and testing of a 19.5 MW captive power plant (7.5 MW and 4.5 MW gas turbine generators, and 3 MW steam turbine).
Executed shutdown activities, including commissioning new panels, panel extensions, and retrofitting breakers.
Education
MBA - Operation
D Y Patil College
Pune
11-2024
B.E. - Electrical Engineering
Mumbai University
12.2011
H.S.C. -
R.K. Talreja College
Ulhasnagar, Maharashtra
12.2007
S.S.C. -
N.R.C. School Mohone
Kalyan, Maharashtra
12.2005
Skills
Expertise in subject matter: electrical
Data Center Management
Project Management
ERP System Operations
Spare and Vendor Management
Effective Multitasking
Customer focus
Stakeholder Collaboration
Accomplishments
Certification for excellence award Q1 FY 22 @ NTT data centre
Super achiever award for FY 2024 @ NTT data centre
Raising star award @ CapitaLand Data Centre
Training
3-days Training Program on Fault Current Calculation and Relay Setting & Relay Co-ordination
Siemens PLC 1200 & HMI with TIA portal
ISO 50001:2018 : Certification for awareness cum Internal auditor of EnMS
Certification
Awareness of EMS ISO 14001:2015
Awareness Cum Internal Auditor of EnMS ISO 50001:2018 and ISO 19011:2018
Languages
English
Hindi
Marathi
Personal Information
Date of Birth: 04/01/90
Timeline
Senior Manager, SME Electrical
CapitaLand Data center
05.2024 - Current
Data Center Manager
NTT global data center and cloud infrastructure
08.2021 - 05.2024
Deputy Manager
Godrej & Boyce Mfg. Co. Ltd
06.2018 - 08.2021
Assistant Manager
Volkswagen India Pvt Ltd
03.2015 - 03.2018
Electrical Engineer
Deepak Fertilizer and Petrochemical Ltd.
06.2011 - 03.2015
Awareness of EMS ISO 14001:2015
Awareness Cum Internal Auditor of EnMS ISO 50001:2018 and ISO 19011:2018
MBA - Operation
D Y Patil College
B.E. - Electrical Engineering
Mumbai University
H.S.C. -
R.K. Talreja College
S.S.C. -
N.R.C. School Mohone
Similar Profiles
CHLOE TAN Xue YingCHLOE TAN Xue Ying
Finance Manager (Budgeting & Forecasting) at CapitaLand (under CapitaLand India Trust)Finance Manager (Budgeting & Forecasting) at CapitaLand (under CapitaLand India Trust)