Summary
Overview
Work History
Education
Skills
Accomplishments
TOOLS & TECHNOLOGIES
Timeline
Hi, I’m

NAVEEN GUNTAPALLI

Senior Test Engineer
Bengaluru

Summary

Results-driven AMISP/AMI Test Engineer with 4 years of experience in HES platform validation and MDM integration testing. Achieved over 15 REC empanelments without rejections, ensuring compliance with DLMS/COSEM protocols and maintaining zero regulatory non-conformances. Skilled in TCP/IP communication verification and AMI integration lifecycle management, with a focus on effective testing strategies that enhance product reliability and support team collaboration.

Overview

5
Languages
5
years of professional experience

Work History

BCITS PVT LTD

Senior Test Engineer
06.2023 - Current

Job overview

  • Led comprehensive HES platform functional, regression, and system integration testing for the AMI stack — Smart Meters, HES, MDM, WFM, and RF/Cellular layers — ensuring zero data flow failures across all nationwide DISCOM deployments.
  • Executed HES-to-MDM integration verification across PGVCL, MGVCL, DGVCL, PVVNL, and SBPDCL DISCOM projects, validating meter-data pipeline integrity, billing data accuracy, protocol conformance, and communication reliability at scale.
  • Validated end-to-end DLMS/COSEM (IEC 62056) protocol compliance, ensuring accurate OBIS code verification, APDU parsing, GET/SET/ACTION service validation, client-server association setup/teardown, and push-notification testing across meter-to-HES communication layers.
  • Performed TCP/IP and DLMS protocol interoperability testing for meter-to-HES sessions, verified transport-layer reliability, encrypted DLMS transmission over TCP/IP, session management, and error recovery under simulated network-fault conditions.
  • Conducted MDM data integrity validation: 15/30-minute interval load profiles, power quality events, tamper alarms, demand records, and billing parameters — confirmed zero data loss from HES to MDM across all test cycles.
  • Designed and executed HES remote-command test cases: connect/disconnect relay control, demand reset, load-profile retrieval, time synchronization, and parameter read/write — validating full bidirectional meter-HES control flow.
  • Verified HES alarm and event-management workflows: tamper detection, power outage, communication failure, voltage deviation, and billing-cycle alerts — confirming 100% alert propagation accuracy to MDM, and WFM layers.
  • Achieved zero regulatory non-conformances across three ISO 15959 and IEC 62056-compliant smart meter product launches, directly enabling regulatory approval and market entry.
  • Managed 15+ REC empanelment processes, PGCIL type testing, Factory Acceptance Tests (FAT), and Site Acceptance Tests (SAT) across nationwide AMI projects — zero compliance rejections.
  • Supported large-scale AMI project acceptance for Apraava Energy, IntelliSmart, and GMR — field validation, HES connectivity verification, and formal sign-off coordination.
  • Validated LoRaWAN HES integration for smart water meters and smart street light systems — bidirectional communication, remote-command execution, and end-to-end data integrity.
  • Smart Meter and Firmware Validation
  • Executed TCP/IP stack verification, ensuring socket-level communication, packet integrity, timeout and retransmission handling, and error recovery, which maintained 99.9% stability of meter-to-HES link under adverse network conditions.
  • Validated RF NIC and 4G GPRS/Cellular module performance: signal integrity, handoff behavior, protocol conformance, and reliable data delivery between meters and HES.
  • Participated in agile development practices, enhancing product iterations and contributing to improved quality assurance outcomes.
  • Contributed to cross-functional teams, ensuring timely delivery of high-quality products.

CYIENT LTD

Embedded Software Engineer
05.2022 - 11.2022

Job overview

  • Led the feature ownership and verification for the automotive radio module for US and European vehicle variants, managing the complete V&V lifecycle from requirement analysis through formal OEM sign-off.
  • Authored and executed CAPL scripts in CANoe/CANalyzer for stress testing, fault injection, and boundary verification across 4 major software releases on 10-inch and 5-inch infotainment platforms.
  • Executed manual firmware upgrade, downgrade, and rollback validation, achieving a 100% successful rollback recovery rate with zero regression defects.
  • Uncovered 15+ latent firmware defects via BVA and equivalence partitioning on firmware input parameters before software freeze milestones.
  • Performed manual firmware upgrade, downgrade, and rollback validation, ensuring 100% successful rollback recovery with zero regression defects.
  • Performed HIL stability testing on client test bench, validating system behaviour under real-world CAN signal conditions.
  • Developed 300+ structured test cases and test specifications in DOORS from HMI flowcharts, vehicle functional requirement documents, and switch matrix inputs — maintained 100% requirement traceability.
  • Collaborated with cross-functional teams to develop high-quality, reliable software for various embedded systems applications.
  • Coordinated with cross-functional teams to deliver reliable software for embedded systems applications, enhancing product quality.
  • Assisted in hardware troubleshooting efforts alongside engineering teams, providing valuable insight into potential software-related issues.
  • Translated technical concepts and information into terms parties could easily comprehend.

APPLIC SOLUTION LLP

QA Engineer
08.2021 - 05.2022

Job overview

  • Planned, designed, and executed 40+ manual test cases using a structured Python-based test framework, reducing regression cycle time by 30%, and overall QA cost by 20%.
  • Contributed QA insights during agile practices, including sprint planning and daily stand-ups, enhancing team collaboration and project outcomes.
  • Conducted daily manual functional, regression, and black-box testing — BVA and equivalence partitioning — against system requirements and user stories.
  • Executed automated test suites to assess performance, functionality, and scalability, supporting quality assurance objectives.
  • Performed nightly-run analysis in virtual machine environments; generated structured defect reports, improving defect tracking accuracy by 35%.
  • Maintained requirement-to-test traceability matrices, ensuring full coverage visibility, defect auditability, and sprint readiness.
  • Managed bug tracking systems, ensuring timely resolution of reported issues and maintaining clear communication with stakeholders.
  • Maintained requirement-to-test traceability matrices for full coverage visibility, defect auditability, and sprint readiness, facilitating effective QA processes.

Education

Avanthi Institute of Engineering and Technology
Hyderabad

B.Tech from Electronics and Communication Engineering
06-2018

University Overview

Skills

MDM integration testing

AMI system testing

Smart meter testing

Field acceptance test (FAT)

HES validation

DLMS compliance

ISO compliance testing

Accomplishments

Accomplishments
  • 15+ REC empanelments & PGCIL type tests — zero compliance rejections; directly enabled AMI business expansion across RDSS and KWF national projects.
  • Zero regulatory non-conformances across 3 ISO 15959 / IEC 62056-compliant smart meter launches — direct contribution to regulatory approval and market entry.
  • Zero field failures across 10+ embedded smart metering device validations — 3 consecutive product releases deployed defect-free post-deployment.
  • HES-to-MDM integration verified across 5 major DISCOM projects — zero data pipeline failures and zero protocol non-conformances in production.
  • 100% rollback recovery rate across all OTA and manual firmware upgrade/downgrade cycles at BCITS and Cyient.
  • 40% defect detection improvement through systematic BVA, equivalence partitioning, and edge-case test design across firmware V&V cycles.
  • 300+ DOORS test cases authored for automotive V&V — 100% requirement coverage, formal OEM stakeholder sign-off achieved.
  • DLMS/COSEM and TCP/IP protocol compliance validated across full smart meter product lines — zero protocol non-conformances in any REC or PGCIL certification cycle.

TOOLS & TECHNOLOGIES

TOOLS & TECHNOLOGIES
  • AMI / HES / MDM: HES Platforms, MDM, WFM, AMI Stack, Smart Meters
  • Protocols: DLMS/COSEM (IEC 62056), TCP/IP, LoRaWAN, 4G GPRS, RF NIC, Modbus, OTA
  • Automotive: CANoe, CANalyzer, CAPL, HIL, JTAG, UART, SPI, CAN Bus
  • Test Management: Jira, DOORS, ALM/QC, Bugzilla, AI Log Analysis
  • Standards: ISO 15959, IEC 62056, MISRA C, ISO 26262 (Awareness)
  • Programming: Python, SQL, Shell Scripting, XML/JSON

Timeline

Senior Test Engineer
BCITS PVT LTD
06.2023 - Current
Embedded Software Engineer
CYIENT LTD
05.2022 - 11.2022
QA Engineer
APPLIC SOLUTION LLP
08.2021 - 05.2022
Avanthi Institute of Engineering and Technology
B.Tech from Electronics and Communication Engineering
NAVEEN GUNTAPALLISenior Test Engineer