Great Versatile Over 22 years of rich and dynamic experience in Water Treatment Plant Operation (Ion Exchange & Reverse Osmosis) and Waste Water Treatment Plant Operation (WTP, ETP/STP)., I have fully take over of WTP (RO-DM Plant System), WWTP Plant (ETP/STP), MEE Plant, Cooling Tower System and Quality Control department very hygienic and systematic condition., Having a very good experience in Erection, Pre-commissioning & Commissioning Activity (250 m3/Hr of RO with DM Plant Operation)., Reviewed of vendor schedule for erection & commissioning to complete the project within the time., Conducted daily meeting to expedited project activities., Having experience with Permit To Work System (PTW)., To maintained the records / log books for the important field readings and all lab water test parameter readings., Systematic cleaning of RO membranes and chemicals washing., We have skilled performance of aerobic & anaerobic process for ETP Plant., We have maintained COD reduction as per our Pollution Control Norms., Co-operation and co-ordination with site engineer and field operators during cleaning of membranes, removing and reloading of new membranes., Preparation and submission of regulatory documents like water & environmental monitoring analysis and monthly complied report and quarterly monitoring report was made as per our Government Pollution Control Norms (SPCB & CPCB)., Responsible for instrument operation and calibration as per schedule using current version of specification and STP., Basic Sediment & Water Analysis was carried out in Crude Oil by centrifuge method., Polymer samples Concentration & Viscosity Analysis was carried out., We have followed ASTM Procedure & APHA Standard Test Method., We have followed GLP, GDP, GMP & QMS As per Regulatory Requirements., Raw Material, In-process, Intermediate & Finished Product samples were analysed by Wet Method & Instrument Method., Responsible for analysis reviewer and data updated in LIMS., Responsible and Performed to maintained the Laboratory Instruments/Equipments Effectively Through 5S Activities., Implementing and Maintaining of Quality Management System ISO 9001:2000, Environmental Management System ISO14001 and FOOD SAFETY SYSTEM HACCP., Trained on chemical handling, Plant Safety, First Aid and Fire Fighting etc., Energy Conservation, HAZOP Identification, MSDS, Internal Auditor (ISO:9001 and ISO:14000), 725m3/day, Equalization, Neutralization, Air Stripper, Primary Clarifier, Anaerobic Filter (2 Stage), Aerobic Digestion, Pre Aeration, Flash Mixer, Clariflocculator, Submergible Aerator Fixed Film Reactor (SAFF), Parallel Plate Separator (PPS), Secondary Aeration, Secondary Clarifier, Chlorine Content, Final Blending, Gas Chromatography – Lab Solution and Iris 32 Software (TCD and FID Detectors), High Performance Liquid Chromatography – Lab Solution and Chromeleon Software., UV-Visible Spectrophotometer - Shimadzu & Hach, Cannon Fen Sky Viscometer & DV III ULTRA Viscometer (Brookfield), Sieve Shaker – Particle Size by ASTM Method, Karl Fisher Titrator – Metrohm & Lasco, Flame Photometer - Elico, IR & TOC Analyzer – Shimadzu, CO/CO2 Analyzer - Siemens, pH and Conductivity Mettler Toledo – (LabX Software & Spectral Lab), Melting Point Apparatus & Bulk Density Apparatus., Hydrazine, Morpholine and Silica in Boiler Feed Water (Using Spectrophotometer), Phosphate and Iron content in Cooling Water (Using Spectrophotometer), Waste Water Analysis: (ETP As Per Our TNPCB): Chemicals Oxygen Demand, Biological Oxygen Demand, MLSS, MLVSS, DO, TDS, TSS, Sulphate and Hexavalent Chromium etc., Demineralized Water Analysis: PH, Conductivity, Sodium, Potassium, Silica, Nitrates and Heavy Metals., Raw Water Complete Analysis: PH, Conductivity, Sodium, Potassium, Total Hardness, Total Alkalinity, Chloride, Sulphate, Iron, Silica, TS and TDS etc., Purified Water: PH, Conductivity, Nitrate, Heavy Metals and TOC.