Results-driven Instrumentation Manager with over 3 years of experience at the world's largest refinery, excelling in automation engineering, maintenance, and project management. Adept at troubleshooting, safety management, and material coordination, with expertise in calibration, commissioning, and control system modifications. Proficient in SAP MM for spare management and project documentation. Skilled in leadership, communication, and Microsoft Office, with a strong background in materials management and a commitment to delivering high-quality results. Known for implementing strategies for cost savings and resource optimization, recognized for developing a database system that improved data accuracy, and reduced manual errors. A proactive professional with a proven track record in overseeing complex projects and driving operational excellence.
COMISSIONING OF FFP (Feed Flexibility Project)
FCC (Fluidized Catalyst Cracker), INSTRUMENT (Pressure/Flow/Temperature/level) Transmitter INSTALLATION, CONFIGURATION UPTO DCS, NEW PANEL INSTALLATION & WIRING TERMINATION, COLD LOOP CHECKING - FROM FIELD INSTRUMENT TO PANEL, DCS MARSHALLING AND SYSTEM PANEL INTERNAL WIRING AND CABLE LAYING, IRP (INTERPOSING RELAY) PANEL COMISSIONING, Fire& Gas DEVICE LOOP CHECKING AND Cause & Effect Checking, HOT LOOP CHECKING - FROM FIELD INSTRUMENT TO DCS HMI GRAPHICS, CONFIGURATION OF ANALOG & DIGITAL INPUT/OUTPUT SIGNALS IN DCS SYSTEM USING CONTROL NARRATIVES, SIEMENS PLC Commissioning, ESTABLISHES SERIAL LINK CONFIGURATION BETWEEN DCS AND SEIMENS PLC, CEMS Analyzer Commissioning MOCs (MANAGEMENT OF CHANGE), Chlorine scrubber in cooling tower, Instrument (Level Transmitter/On-off Valve/Pressure Gauge) installation/configuration/alarm configuration, Logic development in Foxboro DCS, Fire & Gas Toxic Gas detector installation/Configuration and Logic Checking, Logic modification in DCS blocks, 2oo3(2 out of 3) SOV implementation in critical Valve, Cable lying/4 Solenoid Valve installed, 2oo3 Voting Logic Implemented in Emergency Shutdown System(ESD/PSS). TURNAROUND/SHUTDOWN ACTIVITIES, Compressor, Vibration/Speed Probe Checking/Calibration using TK-3, Cause & Effect Checking, Anti-Surge valve Calibration, System, Barrier/Power Supply Replacement & installation, Relays and barrier replacement, Logic modification and changes in DCS system control blocks using control narratives, C&E checking in ESD system and updation of the same., PID tuning of controllers as per requirement., AB PLC Control Logix 500, Logic Checking, Bypassing Interlocks, Firmware Upgradation