Offering almost 12 years of experience in Field, out of which over seven and a half years of experience in Electrical Maintenance of a coal-based power plant and four and a half year of experience in Quality department at Sterling and Wilson Private Limited in MEP vertical
Gujarati, Hindi, English
· Hands-on-experience in preventive, predictive, breakdown maintenance and testing of major and running auxiliaries of a power plant including 110 MW Generators and accessories, Control Relay Panels, Synchronizing panel, 132kV & 66kV Air insulated Switchyards, 6.6 kV & 3.3 kV HT Motors, LT motors up to 132kW, 140MVA Generator Transformers and associated electrical apparatus, 110 MW Digital Voltage Regulation Static Excitation System, Electro static precipitator and all associated Rectifier panels, Field switch mechanism, DERM, CERM mechanism Numerical Relays.
· Hands-on experience in preventive, predictive and breakdown maintenance of 11kV, 6.6kV, 3.3kV rated HT panels and vacuum circuit breakers, 415V LT Panels and LT Air Circuit Breakers, Variable Frequency Drives rated up to 132kW,. Ash slurry electrical system, 220V DC and 110V DC battery charger and DCDB system.
· Hands-on-experience in preventive, predictive and breakdown maintenance of major and running auxiliaries of Coal Handling Plant including twin VFD based 155 degree Wagon Tippler and other associated hydraulic accessories, Conveyor Belt systems and their protection and interlocking system etc.
· Handling all planned shutdown related activities as a shutdown co-ordinator representing Electrical Maintenance Department. Co-ordinating with operation, planning and procurement department for material and resource management related activities. Procurement/hiring related material and manpower services required during planned shutdown activities.
· Looking to my ability and availability to manage & trouble shoot plant related issues, involvement and skills in preparing technical specifications for services and material management, handling manpower and resource management skills, involvement in acquiring ISO 9001:2008, ISO 14001:2015, ISO 50001:2011, ISO 18001:2008 certification organization promoted me as an “Assistant Manager-Electrical Maintenance.
· Skilled in areas of Power Plant Maintenance Auditing & Inspection and Resource Management.
CORE COMPETENCIES
· Skilled in scheduled preventive, predictive and breakdown maintenance of all electrical equipment installed in a thermal power plant
· Maintenance and testing of 110 MW Generator and associated accessories like Protection panels, Synchronizing panels, CT, PT, Bus-duct, Digital Static Excitation system, Yoke assembly etc.
· Maintenance and testing of 140 MVA Generator Transformers and associated auxiliary like UAT,NGR.
· Maintenance of HT and LT panel boards, Air circuit breakers, Vacuum Circuit Breakers, HT and LT cables
· Maintenance and testing of Numerical Relays installed in plant for various incoming and outgoing feeders.
· Maintenance of HT and LT motors installed in plant area as a part of preventive, predictive and breakdown maintenance of a plant.
· Maintenance of Electro Static Precipitator and relevant recti-formers, panels, controllers, Ash slurry system during running or planned shutdown activity.
· Maintenance of 110V DC and 220V DC battery charger and battery bank system including DCDB system of the plant.
· Maintenance of 132kV and 66kV switchyard components like power transformers, CT, PT, Isolators SF6 Circuit breakers, Control Relay Panels, SCADA system.
· Maintenance of Wagon Tippler electrical system and relevant VFD panels, CAM switch mechanism Interlocking system and 40 nos. of Conveyor belts and their protection and interlocking system.