GCC Experience: As a Sr. Protection Engineer. M/s Voltage Engineering.

Responsibilities: To test the Directional Over Current & Non Over Current, Pilot wire Differential protection 11KV Protection Routine Maintenance under the Project GTC 478/2012. Client: Qatar Electricity Board.

M/s Powertech Engineering LLC, As a Testing Engineer,

Responsibilities: To test the Electrical Equipments and Commissioning of all 132KV switchyard equipments like Transformer, CT, CB, CVT, Isolator and Earth switch, Control & relay Panels and SCADA Panel. Testing of all kind of Auxiliary Relays and Backup Protection Relay. Testing and Commissioning of 132KV CB Replacement. Client: Petroleum Development Oman.

M/s Technosys Engineers & Consultants Pvt Ltd, As a Protection Engineer. Responsibilities: Testing and Commissioning of 500 MVA Transformers. Testing and Commissioning of Protection Relays such as Distance Relay and Transformer Differential Relay. Testing and commissioning of 400KV Switchyard Equipments like CT, CB, CVT, Isolator and Earth switch. Scheme Checks, Testing and commissioning of 132/33/13.8/11 KV Substation equipments. Scheme checks for 400KV Control and Relay Panels, Commissioning and synchronization.

Domestics Projects: M/s Siemens Ltd. Responsibilities: Study the scope of work and to prepare the client requirements as per the tender documents in technical accepts & testing Coordination with vendors and testing teams.

Electrical Engineering professional with 15+ Years of experience in Electrical Project Execution and Testing Commissioning, Reviewing all engineering design documents providing the inputs to engineering team. Electrical Equipment Testing and Commissioning up to 400KV Rating system. Protection Relay Testing & configuration, Relay Routine Maintains test, Relay Time grading, Protection Relay confirmation and Relay setting Calculation & Confirmation. My Experiences obtained in Oil & Gas, Power Plant and Electrical Transmission & Distribution sectors & Metro Rail projects.

GCC Project Clients: Qatar Electricity Board – (Protection Engineer LOA), Petroleum Development of Oman, Gulf Corporation Council Interconnection Authority (UAE).

India projects clients: NTPC, NHPEL, IOCl, OPTCL, PGCIL, Metro Rail Kolkata.

Overview

17
17
years of professional experience

Work History

(Commissioning Manager) As a Third Party Role.

Siemens Limited
Kolkata (Remote)
04.2023 - 04.2024
  • Managed safety, process and documentation, installation quality, proprietary software and products.
  • Coordinated equipment testing schedules, ensuring timely completion without compromising quality or safety standards.

Technical Manager

JV Power INFRA
Chennai
08.2021 - 03.2023

Substation Manager

Kalpataru Power Transmission Limited
Mumbai
05.2019 - 03.2020

Electrical Power System Engineer

M/s Power Projects
Chennai
08.2016 - 04.2019

Protection Relay Engineer

Voltage Engineering LTD
Qatar (Doha)
09.2014 - 10.2015

Protection Relay Testing & Commissioning Engineer

Power tech Engineering LLC
Oman
09.2012 - 07.2014

Protection Engineer

Techno sys Engineers & Consultants Pvt Ltd
10.2009 - 06.2012

Testing & Commissioning Engineer

Sysprotech Engineers & consultant Pvt Ltd
India
06.2007 - 10.2009

Education

BE - Electrical & Electronics Engineering

SMK Fomra Inst of Tech
Tamilnadu
01.2009

Skills

  • Technical knowledge
  • Equipment testing
  • Training Coordination
  • Design review
  • Cost Control
  • Industry standards
  • Site acceptance testing
  • Commissioning Strategy
  • Pre-commissioning activities
  • Troubleshooting skills
  • Safety assessment
  • Documentation abilities
  • Equipment Installation
  • Equipment Troubleshooting

Languages

English
Tamil
Hindi

Keyhighlights

  • Electrical Protection Relays, Testing & commissioning
  • Testing and Commissioning of all Electrical Equipments rated up to 400KV. Protection Relay co-ordination, protection safety audit, etc.
  • Relays Distance Protection, Transformer Differential Protection, PWD Protection, Line Differential Protection, Directional over current, Back-up Relay and all kind of auxiliary Relay
  • Authorized Electrical Person (AEP) from Petroleum Development Oman (PDO), Oman
  • Kahramaa LOA(Limit-of-Access) Holder As Protection Engineer

Organisationalexperience

  • 04/2023, Present, M/s Siemens Ltd, Kolkata, Commissioning Manager as a third party role
  • 08/2021, 03/2023, M/s JV Power INFRA, Chennai, Technical Manager
  • 05/07/2019, 03/09/2020, M/s Kalpataru Power Transmission, Mumbai, Substation Manager
  • 08/01/2016, 04/20/2019, M/s Power Projects, Chennai, Electrical Power System Engineer
  • 09/01/2014, 10/21/2015, Voltage Engineering LTD, Doha, Protection Relay Engineer
  • 09/30/2012, 07/02/2014, Power tech Engineering LLC, Oman, Protection Relay Testing & Commissioning Engineer
  • 10/2009, 06/2012, Techno sys Engineers & Consultants Pvt Ltd, Protection Engineer
  • 06/2007, 10/2009, Sysprotech Engineers & consultant Pvt Ltd, India, Testing & Commissioning Engineer

Testingdone

  • Primary Injection Test
  • Secondary Injection Test
  • Inter trip scheme checks.
  • Interlock scheme checks.
  • HV, LV & LVAC - REF Sensitivity and Stability checks
  • Transformer Differential Protection Sensitivity and Stability with various possible conditions checks
  • Voltage selection scheme and Synchronizing scheme checks.
  • Testing of Earth mat resistance, step & touch potential.

Testingequipmentsoperated

  • OMICRON CMC 256,356 relay test kit.
  • OMICRON CPC100

Personal Information

  • Age: 39
  • Date of Birth: 06/10/1984
  • Gender: Male
  • Nationality: Indian

Domesticprojects

  • Noapara existing RSS – 33KV- 750V DC.
  • InBetween Noapara to DDC-TSS Substation.
  • DumDum Contonment-TSS Substation.
  • Jassore road-TSS Substation.

Training

  • Safety Training
  • Electrical Sitras Training (SIEMENS) Certified

Disclaimer

I hereby affirm that the particulars furnished are true and accurate to the best of my knowledge and belief.

Timeline

(Commissioning Manager) As a Third Party Role.

Siemens Limited
04.2023 - 04.2024

Technical Manager

JV Power INFRA
08.2021 - 03.2023

Substation Manager

Kalpataru Power Transmission Limited
05.2019 - 03.2020

Electrical Power System Engineer

M/s Power Projects
08.2016 - 04.2019

Protection Relay Engineer

Voltage Engineering LTD
09.2014 - 10.2015

Protection Relay Testing & Commissioning Engineer

Power tech Engineering LLC
09.2012 - 07.2014

Protection Engineer

Techno sys Engineers & Consultants Pvt Ltd
10.2009 - 06.2012

Testing & Commissioning Engineer

Sysprotech Engineers & consultant Pvt Ltd
06.2007 - 10.2009

BE - Electrical & Electronics Engineering

SMK Fomra Inst of Tech
Rajesh G