Electrical engineer with AMPP CP Level 2 certification and extensive hands-on experience in ICCP systems, including CP station construction, anode bed installation, and rectifier installation. Proficient in cable laying, termination, testing, commissioning, and troubleshooting for oil and gas pipeline projects. Expertise in MV/LV electrical works, CP measurements, and drawing interpretation, ensuring adherence to safety, quality, and project specifications.
Overview
3
3
Languages
1
1
Certification
9
9
years of professional experience
Work History
ELECTRICAL ENGINEER (CATHODIC PROTECTION)
Abaja Contracting Company
RASTENURA,DAMMAM
02.2024 - 07.2026
Project: Saudi Aramco CP-OHPL — Cathodic Protection Overhead Power Line
Areas & Well-Heads: UTMN-4085, HWYH-1302, SDGM-1292, UTMN-3195
Executed ICCP system installation and construction activities for the protection of buried pipelines and onshore well casings under the Saudi Aramco CP-OHPL project.
Supervised and performed CP station construction, including installation of TRUs, disconnecting switches, junction boxes, test stations, and associated CP equipment.
Carried out deep-hole drilling,anode installation, cabling, and backfilling of TA-4 ICCP anodes.
Executed positive and negative CP cable laying, routing, termination, and connections to CP equipment and well casings.
Installed and connected anode junction boxes, multipurpose junction boxes, coupon boxes, and test stations
Conducted DS/TA readings, rectifier output measurements, anode current measurements, and system performance checks.
Performed structure-to-electrolyte potential measurements to evaluate CP effectiveness and protection levels.
Conducted holiday testing to verify the integrity of CP cables and identify discontinuities.
Performed CP commissioning, testing, troubleshooting, and functional verification prior to system handover.
Maintained accurate inspection records, test results, cable schedules, and commissioning documentation in accordance with project requirements
Ensured all activities were executed in compliance with Saudi Aramco specifications, approved drawings, applicable CP standards, and HSE requirements.
Electrical Engineer
SAINI HEAVY ELECTRICALS & ENGINEERING CO. Pvt Ltd
MUMBAI
05.2023 - 01.2024
Assisted in MV cable laying and installation, including trench preparation, removal of loose/debris material, and provision of a suitable sand bedding layer.
Laid MV cables over the prepared sand bed with proper spacing, alignment, routing, and bending radius as per approved drawings and site requirements.
Provided a protective sand layer over the installed cables to prevent mechanical damage during backfilling.
Installed cable warning/protection tape at the specified depth above the sand-covered cables for identification and future excavation safety.
Performed trench backfilling and compaction in proper layers using suitable excavated material, ensuring adequate protection and stability of the installed cable route.
Assisted in MV cable glanding, lugging, connection, and termination at switchgear, panels, transformers, and motor terminal boxes.
Conducted MV cable testing and pre-commissioning checks, including insulation resistance, continuity, and phase identification.
Assisted in motor testing and commissioning, including insulation resistance (IR), winding/continuity checks, phase-sequence verification, and rotation checks.
Graduate Engineer Trainee
Brihanmumbai Electricity Supply & Transport Undertaking (B.E.S.T)
Mumbai
05.2022 - 05.2023
Analyzed and interpreted electrical diagrams to enhance understanding of systems Single Line Diagrams (SLDs) to understand electrical power distribution networks and system operations.
Acquired hands-on experience to Operation & Maintenance (O&M), Erection, Metering, Consumer Services, and Street Lighting departments.
Assisted in HV & LV underground cable installation, construction, jointing, and execution of new electrical connection schemes, enhancing connectivity for consumers.
Assisted in underground cable fault detection and fault-location activities using standard testing methods and equipment.
Participated in protective relay testing and VCB rack-in/rack-out operationsGained practical knowledge of RMUs, battery chargers, capacitor banks, and reactors, contributing to effective electrical distribution
Assisted in transformer testing and maintenance, including oil testing, oil filtration, silica-gel replacement, HV/LV magnetizing tests, and phase-sequence testing, ensuring reliability of electrical systems., HV/LV magnetizing tests, and phase-sequence testing.
Gained exposure to the operation and maintenance of Street Light Pillars and Auxiliary Distribution Pillars.
Assisted in outage coordination for VCB maintenance and electrical fault rectification to support safe and reliable power-system operation.
Developed an understanding of consumer metering, billing procedures, and electrical distribution workflows.
Internship Training
Kurla EMU CARSHED
MUMBAI
06.2017 - 07.2017
Assisted in preventive and periodic maintenance of suburban Electric Multiple Unit (EMU) train rakes.
Gained exposure to high-voltage traction systems, including pantograph alignment and power collection mechanisms.
Studied pneumatic brake systems and the diagnostic troubleshooting of heavy-duty air compressors.
Observed the calibration of critical control gear, master controllers, and safety switchgear equipment.
Participated in pre-service safety inspections and testing of Passenger Information Systems (PIS).